Desa LMFP33NR(A) Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Öfen Desa LMFP33NR(A) herunter. Desa LMFP33NR(A) User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 36
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Save this manual for future reference.
For more information, visit www.desatech.com
WARNING: If the information in this manual is not fol-
lowed exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
Immediately call your gas supplier from a neighbors
phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire
department.
Installation and service must be performed by a quali-
fied installer, service agency or the gas supplier.
UNVENTED (VENT-FREE) GAS FIREPLACE
OWNER’S OPERATION AND INSTALLATION MANUAL
LMFP33NR(A) AND LMFP33PR(A) REMOTE CONTROL
GAS FIREPLACE SYSTEMS
Shown with optional cabinet mantel and hearth base accessories.
Patent Pending
Seitenansicht 0
1 2 3 4 5 6 ... 35 36

Inhaltsverzeichnis

Seite 1 - GAS FIREPLACE SYSTEMS

Save this manual for future reference.For more information, visit www.desatech.comWARNING: If the information in this manual is not fol-lowed exactly,

Seite 2 - TABLE OF CONTENTS

www.desatech.com111604-01K10CONVENTIONAL FIREPLACE INSTALLATIONConventional installation of this fireplace involves installing fireplace along with the

Seite 3 - SAFETY INFORMATION

www.desatech.com111604-01K 11Figure 12 - Inserting Fireplace Into Cabinet Mantel INSTALLATIONContinued Actual FramingHeight 32 3/8" 33"F

Seite 4 - IDENTIFICATION

www.desatech.com111604-01K12Mantel Clearances for Built-In InstallationIf placing mantel above built-in fireplace, you must meet minimum clearance betw

Seite 5 - AND VENTILATION

www.desatech.com111604-01K 13Figure 18 - Minimum Mantel Clearances for Built-In InstallationSuppliedFireboxHoodMust BeUsed atAll TimesWire-meshScreenF

Seite 6

www.desatech.com111604-01K14For propane/LP units, the installer must supply an external regulator. The external regulator will reduce incoming g

Seite 7

www.desatech.com111604-01K 15CONNECTING FIREPLACE TO GAS SUPPLYInstallation Items Needed• 5/16" hex socket wrench or nut-driver • Phillips scre

Seite 8

www.desatech.com111604-01K16CHECKING GAS CONNECTIONS WARNING: Test all gas pip-ing and connections, internal and external to unit, for leaks a

Seite 9

www.desatech.com111604-01K 17INSTALLATIONContinuedFigure 26 - Installing Rear and Middle LogsOFFPILOTONMiddle Log (#2)Rear Log (#1)OFFPILOTONFront Log

Seite 10 - INSTALLATION

www.desatech.com111604-01K18OFFPILOTONModels LMFP33PRA and LMFP33NRA1. Place the base of the middle log (#1) in the U-shaped slots of the grate base.

Seite 11

www.desatech.com111604-01K 19Figure 33 - Installing Batteries in ReceiverCoverReceiverSlot4 AA BatteriesBatteryHousingBackup SwitchINSTALLING BATTERIE

Seite 12

www.desatech.com111604-01K2WARNING: Improper installation, adjustment, altera-tion, service or maintenance can cause injury or prop-erty damage. R

Seite 13

www.desatech.com111604-01K20LIGHTING INSTRUCTIONS WARNING• If fireplace has glass doors, never operate this heater with glass doors closed. If y

Seite 14

www.desatech.com111604-01K 211. STOP! Read the safety information on page 20.2. Make sure equipment shutoff valve is fully open.3. Set remote

Seite 15

www.desatech.com111604-01K22Setting Room TemperaturePress the up or down key until the small triangle is to the left of the thermometer icon (

Seite 16 - Supply Tank

www.desatech.com111604-01K 23INSPECTING BURNERSCheck pilot flame pattern and burner flame pat-terns often.PILOT FLAME PATTERNFigure 39 shows a corre

Seite 17 - INSTALLING LOGS

www.desatech.com111604-01K24Figure 43 - Injector Holder On Outlet Burner TubeBurner TubePrimary Air Inlet Holes (Shape of Holes May Vary by Model)Figu

Seite 18

www.desatech.com111604-01K 25POSSIBLE CAUSE1. Ignitor electrode not con-nected to ignitor cable2. Ignitor cable pinched or wet3. Piezo ignitor n

Seite 19

www.desatech.com111604-01K26OBSERVED PROBLEMODS/pilot lights but flame goes out when control knob is re-leasedBurner does not light after ODS/pilo

Seite 20 - OPERATING HEATER

www.desatech.com111604-01K 27TROUBLESHOOTINGContinuedOBSERVED PROBLEMSlight smoke or odor during initial operationMoisture/condensation noticed on wi

Seite 21

www.desatech.com111604-01K28TROUBLESHOOTINGContinued WARNING: If you smell gas• Shut off gas supply.• Do not try to light any appliance.• Do not to

Seite 22

www.desatech.com111604-01K 29SPECIFICATIONS LMFP33NR(A) LMFP33PR(A)Btu (Variable) 23,000/33,000 23,000/33,000Type Gas Natural Gas Propane/LPI

Seite 23 - INSPECTING BURNERS

www.desatech.com111604-01K 3SAFETY INFORMATION WARNING: This product con-tains and/or generates chemicals known to the State of California to cause ca

Seite 24 - CLEANING AND

www.desatech.com111604-01K30ILLUSTRATED PARTS BREAKDOWNMODELS LMFP33PR, LMFP33PRA, LMFP33NR AND LMFP33NRA (SHOWN)174812252021764 325927141315162211101

Seite 25 - TROUBLESHOOTING

www.desatech.com111604-01K 31PARTS LISTThis list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed

Seite 26

www.desatech.com111604-01K32ILLUSTRATED PARTS BREAKDOWNFIREBOXLMFP33PR, LMFP33PRA, LMFP33NR AND LMFP33NRA411148149314992167101412514131615

Seite 27

www.desatech.com111604-01K 33PARTS LISTFIREBOX LMFP33PR, LMFP33PRA, LMFP33NR AND LMFP33NRAThis list contains replaceable parts used in your fireplace.

Seite 28

www.desatech.com111604-01K34ACCESSORIESNOTICE: All accessories may not be available for all fireplace models.Purchase these fireplace accessories fro

Seite 29 - WIRING DIAGRAM

www.desatech.com111604-01K 35_________________________________________________________________________________________________________________________

Seite 30 - ILLUSTRATED PARTS BREAKDOWN

2701 Industrial DriveP.O. Box 90004Bowling Green, KY 42102-9004www.desatech.com111604-01Rev. K11/04NOT A UPC111604 01WARRANTY INFORMATIONKEEP THIS WAR

Seite 31 - PARTS LIST

www.desatech.com111604-01K4SAFETY INFORMATIONContinued1. This appliance is only for use with the type of gas indicated on the rating plate. This ap-p

Seite 32

www.desatech.com111604-01K 5LOCAL CODESInstall and use fireplace with care. Follow all local codes. In the absence of local codes, use the lat-est edit

Seite 33

www.desatech.com111604-01K6PROVIDING ADEQUATE VENTILATION The following are excerpts from National Fuel Gas Code, ANSI Z223.1/NFPA 54, Sect

Seite 34 - ACCESSORIES

www.desatech.com111604-01K 7AIR FOR COMBUSTION AND VENTILATIONContinuedFigure 4 - Ventilation Air from OutdoorsFigure 3 - Ventilation Air from Inside

Seite 35 - 111604-01K 35

www.desatech.com111604-01K8INSTALLATIONNOTICE: This heater is intended for use as supplemental heat. Use this heater along with your primary heati

Seite 36 - WARRANTY INFORMATION

www.desatech.com111604-01K 9MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS Top Left and Bottom Right Sides and Rear 42" 16" 0"Fi