© 2007 DESA Specialty Products™ 598-1311-00
1 Halogen
Lamp
Sensor
Light Control
Requirements
• The Light Control requires 120-volts AC.
If you want to use Manual Mode, the control must be
wired through a switch.
Some codes require installation by a qualifi ed
electrician.
This product is intended for use with the enclosed
gasket and with a junction box marked for use in wet
locations.
Features
Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Photocell keeps the lighting off during daylight hours.
• LED indicates motion was sensed (day or night).
Motion Sensing
Halogen Fixture
Model 5525
3 Wire
Connectors
6 Screws
(3 sizes included)
Gasket
Mounting Bolt
Mounting Strap
OPERATION
* resets to Auto Mode at dawn.
MANUAL MODE
ON-TIME
10 5 1 TEST
10 5 1 TEST
ON-TIME
TEST
AUTO
Move ON-TIME Switch to
1, 5, or 10 minutes
Mode Switch Summary
Flip light switch
off for one second
then back on*
MANUAL MODE
AUTO
TEST
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the cali-
bration time the control will be in the AUTO mode.
Note: When fi rst turned on wait about 1
1
/
2
minutes for
the circuitry to calibrate.
Light Shield
Plastic Hanger
Rubber Plug
Put the ON-TIME switch on the bottom
of the sensor in the TEST position.
Put the ON-TIME switch in the 1, 5,
or 10 minute position.
Manual mode only works at night
because daylight returns the sen-
sor to AUTO.
Flip the light switch off for one sec-
ond then back on to toggle between
AUTO and MANUAL MODE.
Manual mode works only with the
ON-TIME switch in the 1, 5, or 10
position.
This package includes:
Mode: On-Time Works: Day Night
Test
5 Seconds x x
Auto
1, 5, or 10 Min x
Manual
Until Dawn* x
... back on.
1 Second OFF
then...
®
Seitenansicht 0
1 2 3 4 5 6 7 8

Inhaltsverzeichnis

Seite 1 - Halogen Fixture

© 2007 DESA Specialty Products™ 598-1311-001 Halogen LampSensorLight ControlRequirements• The Light Control requires 120-volts AC.• If you want to

Seite 2 - INSTALLATION

2598-1311-00INSTALLATIONFor easy installation, select an existing light with a wall switch for replacement.For best performance, mount the fi xture abo

Seite 3 - SPECIFICATIONS

3598-1311-00TEST AND ADJUSTMENT❒ Turn on the circuit breaker and light switch.Avoid aiming the control at:• Objects that change temperature rapidly,

Seite 4 - TECHNICAL SERVICE

4598-1311-00POSSIBLE CAUSE1. The lamp is positioned too close to the sensor or pointed at nearby objects that cause heat to trigger the sensor. (Repo

Seite 5 - Movimiento

5598-1311-001 Bombilla HalógenaDetectorControl de luzRequisitos• El Control de Luz requiere 120 VCA.• Para usar el Modo Manual, conecte el control c

Seite 6 - INSTALACION

6598-1311-00INSTALACIONPara una fácil instalación escoja una luz con un interruptor de pared.Para un mejor funcionamiento, instale el aparato a casi 2

Seite 7 - PRUEBA Y AJUSTE

7598-1311-00SPECIFICATIONSAlcance . . . . . . . . . . . . . Hasta 21 m (varía con la temperatura del medio am-biente).Angulo de detección . . . Hasta

Seite 8 - SERVICIO TÉCNICO

8598-1311-00SINTOMALa luz no se enciende.La luz se prende durante el día.La luz se prende sin ninguna razón aparente.La luz se prende una vez y luego