VENTED PROPANE
GAS HEATERS
OWNER’S OPERATION AND INSTALLATION MANUAL
WARNING: If the information in this manual
is not followed exactly, a fire or explosion
may result causing property damage, per-
sonal injury, or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do
not use any phone in your building.
Immediately call your gas supplier from
a neighbor’s phone. Follow the gas
supplier’s instructions.
If you cannot reach your gas supplier,
call the fire department.
Installation and service must be per-
formed by a qualified installer, service
agency, or the gas supplier.
WARNING: Improper installation,
adjustment, alteration, service, or
maintenance can cause property
damage, personal injury or loss of
life. Refer to this manual for cor-
rect installation and operational
procedures. For assistance or
additional information consult a
qualified installer, service agency,
or the gas supplier.
Models: GVR65BPA, GVR65PA, GVR50BPA, GVR50PA, GVR35PA
®
Seitenansicht 0
1 2 3 4 5 6 ... 43 44

Inhaltsverzeichnis

Seite 1 - GAS HEATERS

Save this manual for future reference.®VENTED PROPANEGAS HEATERSOWNER’S OPERATION AND INSTALLATION MANUALWARNING: If the information in this manualis

Seite 2 - CONTENTS

10100791VENTING HEATER (continued)INSTALLINGHEATERContinuedProper Size VentTo safely vent heater, the vent connector pipe must be the same diameter as

Seite 3 - INFORMATION

11100791BULK PROPANETANKVENTINSTALLINGHEATERContinuedCONNECTING TO GAS SUPPLYWARNING ICON G 001 CAUTIONNever connect heater directly to the propane su

Seite 4

12100791Figure 7 - Gas Connection* An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is anacceptable alternative to test gauge c

Seite 5 - IDENTIFICATION

13100791INSTALLINGHEATERContinuedCHECKING GAS CONNECTIONSFigure 8 - Manual Shutoff ValvePOOn PositionOff PositionWARNING ICON G001 CAUTIONMake sure ex

Seite 6 - WARNING

14100791INSTALLINGHEATERContinuedINSTALLING RADIANTS WARNING ICON G001 WARNINGCarefully handle the glass panel. Glass edges arerounded and buffed to p

Seite 7

15100791INSTALLINGHEATERContinuedINSTALLING GLASS PANELFor Radiant Models Only1. Locate the glass panel package inside the back of the heater.WARNING

Seite 8

16100791INSTALLINGHEATERContinuedFigure 12 - Inserting Top Edge of Glass Panel intoUpper Glass Retaining ChannelWARNING ICON G 001 CAUTIONMake sure yo

Seite 9

17100791AIR FORCOMBUSTIONANDVENTILATIONWARNING ICON G001 WARNINGThis heater must have fresh air for proper operation. Ifnot, poor fuel combustion and

Seite 10 - INSTALLING

18100791AIR FORCOMBUSTIONANDVENTILATIONContinuedDETERMINING FRESH-AIR FLOW FOR HEATER LOCATIONExample 1: Locating Heater in Unconfined (Open) AreaNOTI

Seite 11

19100791AIR FORCOMBUSTIONANDVENTILATIONContinuedFigure 15 - Ventilation Air from OutdoorsDraft Hood Spillage: This is a hazardous situation. Draft hoo

Seite 12

2100791CONTENTSSECTION PAGESafety Information... 3Product Identification ...

Seite 13

20100791AIR FORCOMBUSTIONANDVENTILATIONContinuedExample 2: Locating Heater in Confined (Closed) AreaNOTICEA confined area has an air volume of less th

Seite 14

21100791OPERATINGHEATERA. This appliance has a pilot which must be lighted by hand. When lighting thepilot, follow these instructions exactly.B. BEFOR

Seite 15

221007915. Wait five (5) minutes to clear out any gas. Then smell for gas, including near thefloor. If you smell gas, STOP! Follow “B” in the safety i

Seite 16

23100791MANUAL LIGHTING PROCEDURE1. Remove lower front access panel on heater.2. Locate pilot. Pilot is attached to the front of burner.3. Follow step

Seite 17 - VENTILATION

24100791INSPECTINGPILOT ANDBURNERFLAMECheck pilot flame pattern and burner flame pattern often.PILOT FLAME PATTERNFigure 19 shows a correct pilot flam

Seite 18

25100791Figure 21 - Correct Burner Flame PatternSharp BlueFlameRaggedYellowFlameFlameLiftingOff ofBurnerFigure 22 - Incorrect Burner Flame PatternsIf

Seite 19

26100791WARNING ICON G 001 WARNINGTurn off heater and let cool before cleaning or servicing.WARNING ICON G 001 WARNINGKeep heater clear and free from

Seite 20

27100791WARNING ICON G001 WARNINGTurn off and unplug heater and let cool before servicing.Unless you need gas supply for testing, shut off manualshuto

Seite 21 - OPERATING

28100791TROUBLE-SHOOTINGContinuedREMEDY1. Fully open manualshut-off valve.2. Press in control knobfully.3. After pilot lights, keepcontrol knob presse

Seite 22

29100791POSSIBLECAUSE1. Manifold pressure istoo low.2. Burner orifice isclogged.1. Burner orifice isclogged or damaged.2. Burner damaged.3. Gas regula

Seite 23

3100791SAFETYINFORMATIONWARNING ICON G 001 WARNINGSIMPORTANT: Read this owner’s manual carefully and completely beforetrying to assemble, operate, or

Seite 24 - PILOT AND

30100791OBSERVEDPROBLEMBurner fails torespond to thermo-stat.Heater produces awhistling noise whenburner is lit.Heater produces aclicking/ticking nois

Seite 25

31100791If you smell gas• Shut off gas supply.• Do not try to light any appliance.• Do not touch any electrical switch; do not useany phone in your bu

Seite 26 - MAINTENANCE

32100791SERVICEPROCEDURESWARNING ICON G 001 WARNINGTurn off and unplug heater and let cool before servicing.Unless you need gas supply for testing, sh

Seite 27 - SHOOTING

33100791SERVICEPROCEDURESContinuedRemoving Burner1. Shut off gas supply toheater.2. Remove lower frontaccess panel on heater.3. Disconnect burner tube

Seite 28

34100791SERVICEPROCEDURESContinuedChanging Burner Orifice1. Shut off gas supply toheater.2. Remove lower frontaccess panel on heater.3. Disconnect bur

Seite 29

35100791TECHNICALSERVICEYou may have further questions about installation, operation, or troubleshooting.If so, contact DESA International’s Technical

Seite 30

36100791Note: Use only original replacement parts. This will protect your warranty cover-age for parts replaced under warranty.Parts Under WarrantyCon

Seite 31

37100791ACCESSORIESBLOWER KIT - PART NUMBER GA6010For all models. Provides better heat distribution.Makes heater more efficient. Complete installation

Seite 32 - PROCEDURES

38100791ILLUSTRATEDPARTS LISTBlowerAssemblyThis list contains replaceable parts used in your heater. When ordering parts, follow theinstructions liste

Seite 33

39100791ILLUSTRATEDPARTS LISTCabinetAssembly forRadiant ModelsThis list contains replaceable parts used in your heater. When ordering parts, follow th

Seite 34

4100791SAFETYINFORMATIONContinuedWARNING ICON G001 WARNINGS Continued7. Provide the following minimum heater clearances from combustibles (as viewedfr

Seite 35 - TECHNICAL

40100791ILLUSTRATEDPARTS LISTBurnerAssembly forRadiant Models348101112567912131415161718197272972835 Model Only650 and 65Models113130164 24 2326252

Seite 36 - CENTRALS

41100791PARTS LISTBurnerAssembly forRadiant ModelsThis list contains replaceable parts used in your heater. When ordering parts, follow theinstruction

Seite 37 - ACCESSORIES

42100791NOTES_________________________________________________________________________________________________________________________________________

Seite 38 - Assembly

43100791NOTES_________________________________________________________________________________________________________________________________________

Seite 39 - Radiant Models

LIMITED WARRANTYGVR/GVC VENTED PROPANE GAS HEATERSLIMITED ONE YEAR WARRANTYThis DESA product is warranted to the original purchaser to be free from de

Seite 40

5100791PRODUCTIDENTIFICATIONLower FrontAccess PanelControlKnobBlower Switch(on modelsequipped withblower)IgnitorButtonBurnerRadiantsFigure 1 - Vented

Seite 41

6100791Install and use heater with care. Follow all local codes. In the absence of localcodes, use the latest edition of the following:• National Fuel

Seite 42

7100791INSTALLINGHEATERContinuedLOCATING HEATERWARNING ICON G001 WARNINGMaintain the minimum clearances shown in Figure 3,below. If you can, provide g

Seite 43

8100791Note: Venting/chimney materials are not supplied with heater.VENTING HEATERINSTALLINGHEATERContinuedWARNING ICON G001 WARNINGWhen venting this

Seite 44 - WARRANTY INFORMATION

9100791INSTALLINGHEATERContinuedHeater must be vented to the out-doors. Never vent heater to anotherroom or inside a building.The vertical section of

Verwandte Modelle: GVR65BPA | GVR35PA | GVR65PA | GVR50BPA |

Kommentare zu diesen Handbüchern

Keine Kommentare